OMRON Professional Digital Blood Pressure Monitor FAQ

1. Can I import and export the Omron HEM-747IC information to an Excel spreadsheet?
Yes, you would go to File, open patients data information, then go to File, export, and then in file name put patients name. Save the information in designated drive. Open Excel, open file (yellow folder) go to patients name, open the information.

2. Can the HEM-907 be used with a patient receiving supplemental oxygen therapy?
It is not recommended to use the HEM-907 with supplemental oxygen therapy.

3. Can you replace the batteries in the HEM-747IC unit and retain the readings that are in the unit memory?
Yes, you can take the batteries out of the unit and not lose the blood pressure readings. The only time the readings are lost is when you Get the Data from Device, and send a new schedule to device.

4. Does the Omron HEM-907 Blood Pressure Monitor contain mercury?
The HEM-907 contains no mercury.  mmHg is a standard term for blood pressure measurement.

5. I could not complete the install of Omron IC Diskette Software for the HEM-747IC unit. The message stated additional memory is needed. How do I complete the install?
You need to download from Microsoft website for additional memory for the PC. Go to: http://Support.microsoft.com/support/downloads/DP2722.ASP. This information will give you enough memory to complete the install.

6. I received the message "Cannot Find Device" while using the HEM-747IC software. How do I correct this?
Go to Tools, Options,and make sure Auto Detect is selected. Unplug the cable to the monitor, then replug the unit in and make sure the unit is turned on before sending schedule to device. If you have palm pilot or hot sync make sure these devices are turned off. If these are turned on it will interfere with sending schedule to device. If you are using a Gateway computer you must attach the cable to the hard drive first, then install the software. You can also change the RS232 cable and if this still does not work, send the unit to our  repair department, it may be the blood pressure monitor itself.

7. I'm installing the CD-ROM version of the HEM-747IC program on my computer and it does not self execute. How do I correct this?
If this happens go to "My Computer" and click on your CD-ROM drive to start loading driver. After driver is loaded, shut computer off and start computer with Keyspan USA-19QW RS232/USB adapter connected. Be sure to wait till computer shuts down before connecting Keyspan/RS232 adapter. (Keyspan/RS232 adapter must be connected to the computer prior to starting computer. If Omron IC monitor fails to connect to computer, reboot computer with Keyspan/RS232 adapter connected.)

8. I'm receiving the Range Check Error message when I print the HEM-747IC reports. How do I correct this error?
First make sure all other software programs are closed. Be sure that you have all Components selected in the options screen. Go to Tools, Options, click on Report Tab, and make sure all component boxes are checked off and then click OK. If you still receive Range Check Error, you will have to print each window (Report) separately by opening each report sheet and then click on the printer icon. After you shut your system down you should not have this problem.

9. Is the CHECK Mode used to check pressure accuracy with the HEM-907?
The accuracy of the pressure display can be checked in the CHECK mode.   To check the monitor, you will need the following:

1. Calibrated mercury manometer (including inflation bulb)
2. T- tube
3. Two (2) air tubes
4. A sturdy cylindrical shaped object on which the cuff is wrapped

10. What does the AVG Function work seton the Omron HEM-907 Blood Pressure Monitor?
The AVG Function allows you to set the following parameters:

*   Number of measurements desired up to three (3)
*   Waiting time until the first measurement
*   Measurement interval for the AVG Mode   

11. What does the MODE Indicator regulate on the Omron HEM-907 Blood Pressure Monitor?
The MODE indicator provides the flexibility of the following features:

 SINGLE:  Takes one measurement
 AVG:   Averages two (2) or three (3) measurements
 MANU:

 Automatic inflation and deflation with pressure display for auscultation (no blood pressure)
 

 CHECK:   Accuracy of pressure display can be checked in the CHECK Mode

12. What does the P-SET (Pressure Setting) Knob regulate on the Omron HEM- 907 Blood Pressure Monitor?
The P-SET (Pressure Setting) knob regulates the method of function:  automatic or manual.  The automatic setting inflates the cuff via IntelliSense to the patient's optimal pressure according to the patient's blood pressure. The manual inflation settings range from 100-to 280 mm/Hg.

13. What does the Pulse Level Indicator display on the Omron HEM-907 Blood Pressure Monitor?
The Pulse Level gives the number of irregular pulses: The pulse wave having a difference of more than 25% from the average interval of pulse waves is determined irregular. Number of irregular pulse waves is displayed up to three times. 

14. What happens if an error occurs during measurements when using the HEM-907?
When the first error occurs during measurement, the unit will automatically restart the measurement.  IF a second error occurs, the unit will automatically turn off.

15. What is the procedure to change the set values on the OMRON HEM-907 Blood Pressure Monitor?
The procedure is diagramed on page 13 of the Instruction Manual.  The following illustrate the method of changing the set values:

1.  F1 will be displayed by turning the power OFF and then pushing the ON/OFF Button for more than three   seconds while holding the START Button
2.  Push the START Button and select the function to set from F1 to F3.  Each time you push the START  Button, the functions change in the order of F1--F2--F3--
3.  Push the DEFLATION (deflation control)/Measurement Result Display Switch Button and change the set values
4.  When the setting is finished, push the ON/Off (power) Button to turn off the power

The settings are now programmed. Parameters will remain until the unit is reprogrammed with new settings

16. What is the purpose of the Event Button on the Omron HEM-747IC Blood Pressure Monitor?
Normally the doctor sets the  parameters when the patient should use the event button. It can be used if the patient is feeling faint, or after the patient takes medication to see if it's working. The monitor needs to be turned on, and then press the event button. This will show up on the reports as a red dot.

17. What optional accessories are available for the Omron HEM-907 Blood Pressure Monitor?
Optional accessories sold separately include:  Cuffs, Bladders, Mobile Stand, Wall Mounting Kit, AirTube.

18. What purpose does the HIDE button perform on the Omron HEM-907 Blood Pressure Monitor?
The HIDE Button switches display and non-display of measured results. This function can be used in the SINGLE and AVG Modes. When using the HIDE feature the patient will not be able to view the readings

 

 

Send this site to a friend! (click here)


*   Same day and next day shipments are normally the case with the exception of any out-of-stock items.
**
Lifetime member discounts are subject to member terms & conditions. Also, use of this site & products sales that result from this site are subject to our  company's policies & disclaimers


Product Home Page Features & Benefits Symptoms & Conditions
Blood Pressure FAQ Instructions Error Codes LifeStyle Tips OMRON
Specs Step Study Trouble Shooting Buy This Product