AlcoMate/CA2000 Product Instructions:

1) Turn on the PWR On/Off switch

Soon after the power on, CA 2000 will start the countdown 200 to 000 on the display window. – It is a “Warm-up” process to make the sensor and circuit be ready for testing.

2) When you hear beep sound & green lighting is on READY, please blow into for 4.5 seconds till you would hear another time of “Beep” sound.

 N.B. :
1.In this stage, if you don’t blow within 30 seconds, it automatically shows OFF display for turn-off
2. In case you drink quite a little (if actual concentration would be below 0.01%BAC/0.05mg/l  BRAC), it may not be activated. However, it shows still 0.00% and you’re said to be in safe range.

3) Then, after 4.5 seconds while both READY and WARN lamps are flickering, the test result (BAC or BRAC) will be displayed by 3 digits for 15 seconds.

N.B. :
1. If the BAC / BRAC data would be over 0.05% / 0.25 mg/l (default setting) respectively,  red
WARN lamp will be flickering along with “Alarm” sound.
2. The “Alarm” level is adjustable pursuant to the local legal limit.

4) Finally, it shows “OFF” for turn-off.

5) For the successive testing, try again from No.1 to No. 3.

Precautions

1) After drinking, it is recommended to test after 30 min.

It is because it takes 30 min. approximately for alcohol to be absorbed into blood from the digestive organs. And residual alcohol remaining in the mouth may cause inaccurate data.

2) To avoid testing under strong wind or in the closed room with contaminated air.

3) When the “BAT LOW” lamp is lighting on, it’s advisable to replace 9V alkaline battery.

4) To attain more accurate data, please repeat testing about 3 times.


Product Home Page Features & Benefits Symptoms & Conditions
Product FAQs Product FAQs Instructions ABO Blood Type Calculator
Conception Calculator Exclusion Report Report Explanation
Eye Color Inheritance Chart Inclusion Report Determined Results
Buy This Product


*   Same day and next day shipments are normally the case with the exception of any out-of-stock items.
** Lifetime member discounts are subject to member terms & conditions. Also, use of this site & products sales that result from this site are subject to our  company's policies & disclaimers
 

Click to verify BBB accreditation and to see a BBB report.  
 



Test Medical Symptoms
6633 Ashman Rd. Maria Stein, OH 45860
PH: 1-888-595-3136
PH: 1-419-586-9462
FX: 1-775-703-6393

Email Us

Copyright
2001-2009
Family-Run
 Business
Since 2001
Authorized
CardioChek Dealer
Better
Business
Bureau
At Rating
SSL Secured
Checkout
Payment Types
Accepted
Shipping
& Tracking

Send this site to a friend! (click here)